MicronMembrane » RO Membrane » MCBW-8040HF – AG-400 Equivalent
Suez GE AG-400 RO Membrane Element Replacement Equivalent
  • Product num: MCBW-8040HF
  • Equivalent: AG-400 Equivalent

General Information

MCBW-8040HF is manufactured as an equivalent, direct replacement, alternative, analog, retrofit and analogue for Suez GE AG-400 (AG400) RO (reverse osmosis) membrane.MCBW-8040HF reverse osmosis membrane elements are developed for brackish water treatment, ideal for reverse osmosis plant managers and operators dealing with brackish water with pre-treatment.This reverse osmosis membrane element provides consistency, high permeate water quality, high performance and productivity, and long service life.

Features & Advantages

  • Provides high-quality permeate water
  • Stable salt rejection rate and high permeate flow rate
  • Optimized design, good resistance to fouling results in long service life
  • High chemical tolerance for cleaning with highly effective cleaning performance
  • Simple and economical element replacement

Applications

  • Industrial pure water
  • Industrial wastewater reuse
  • Slightly contaminated water

Specifications

  • Configuration: Spiral wound element
  • Membrane Polymer: Polyamide thin-film composite

Performance

Element Model Membrane Active Area
ft2 (m2)
Feed Spacer
mil (mm)
Permeate Flow Rate*
GPD (m3/d)
Stabilized Salt Rejection** Minimum Salt Rejection
MCBW-8040HF 400 (37.2) 28 (0.712) 11,000 (41.6) 99.7% 99.5%

Standard test conditions:The above performance is initial(data record after 30 minutes of operation), based on the following conditions:2,000 ppm NaCl solution225 psi (15.5 bar) operating pressure25°C (77°F) operating temperature15% permeate recovery7.5-8 pH range*Permeate flow for individual elements may vary but will be no more than ±15%.**Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending on feed water characteristics and operating conditions.

Element Dimensions

Length A
inch (mm)
Diameter B
inch (mm)
Permeate tube inner diameter C inch (mm)
40 (1,016) 7.9 (201) 1.125 (28.6)

Operating and Cleaning Limits

Maximum Operating Pressure 600 psi (41 bar)
Maximum Operating Temperature 45°C (113°F)
Maximum Chlorine Concentration 0.1 ppm
pH Range, Continuous 2-11
pH Range, Cleaning 1-13
Maximum Feed SDI (15 mins) 5
Maximum Element Pressure Drop 15 psi (1 bar)
Maximum Feed Flow 17 m3/h
Minimum Ratio of Concentrate to Permeate Flow for Each Element 5:1