- Product num: MCBW-8040HF
- Equivalent: AG-400 Equivalent
General Information
MCBW-8040HF is manufactured as an equivalent, direct replacement, alternative, analog, retrofit and analogue for Suez GE AG-400 (AG400) RO (reverse osmosis) membrane.MCBW-8040HF reverse osmosis membrane elements are developed for brackish water treatment, ideal for reverse osmosis plant managers and operators dealing with brackish water with pre-treatment.This reverse osmosis membrane element provides consistency, high permeate water quality, high performance and productivity, and long service life.
Features & Advantages
- Provides high-quality permeate water
- Stable salt rejection rate and high permeate flow rate
- Optimized design, good resistance to fouling results in long service life
- High chemical tolerance for cleaning with highly effective cleaning performance
- Simple and economical element replacement
Applications
- Industrial pure water
- Industrial wastewater reuse
- Slightly contaminated water
Specifications
- Configuration: Spiral wound element
- Membrane Polymer: Polyamide thin-film composite
Performance
Element Model | Membrane Active Area ft2 (m2) | Feed Spacer mil (mm) | Permeate Flow Rate* GPD (m3/d) | Stabilized Salt Rejection** | Minimum Salt Rejection |
MCBW-8040HF | 400 (37.2) | 28 (0.712) | 11,000 (41.6) | 99.7% | 99.5% |
Standard test conditions:The above performance is initial(data record after 30 minutes of operation), based on the following conditions:2,000 ppm NaCl solution225 psi (15.5 bar) operating pressure25°C (77°F) operating temperature15% permeate recovery7.5-8 pH range*Permeate flow for individual elements may vary but will be no more than ±15%.**Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending on feed water characteristics and operating conditions.
Element Dimensions
Length A inch (mm) | Diameter B inch (mm) | Permeate tube inner diameter C inch (mm) |
40 (1,016) | 7.9 (201) | 1.125 (28.6) |
Operating and Cleaning Limits
Maximum Operating Pressure | 600 psi (41 bar) |
Maximum Operating Temperature | 45°C (113°F) |
Maximum Chlorine Concentration | 0.1 ppm |
pH Range, Continuous | 2-11 |
pH Range, Cleaning | 1-13 |
Maximum Feed SDI (15 mins) | 5 |
Maximum Element Pressure Drop | 15 psi (1 bar) |
Maximum Feed Flow | 17 m3/h |
Minimum Ratio of Concentrate to Permeate Flow for Each Element | 5:1 |
The limits shown above are for general applications. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane element.